5. Conclusions
In this paper the author has proposed a novel method that utilizes two ring-shaped electrodes for lightning protection of wind turbines. The most important and innovative point of the proposed system is a pair of ringshaped electrodes arranged with a narrow gap, where the air discharges to flow the surge current when a lightning strikes the wind turbine.1/100 downsized model of a wind turbine with ring electrodes was manufactured. The results of impulse experiments clearly showed that the proposed model can operate safely.
Especially, when the gap between the two rings is larger than the distance between the upper ring and the nacelle, it is clear that a spark-over certainly occurs and the lightning protection system functions satisfactorily.The author is also investigating FDTD electromagnetic calculations for the present model [10,11].It was confirmed that the results of the calculations also agree well with the experimental results.
problems remain for the proposed method. For example, the method of fixation and installation costs need resolving from a civil engineering viewpoint. Also, any adverse impact on power generation capacity should be discussed from the viewpoint of fluid dynamics. However, in respect of lightning protection, i.e. utilized capacity and generating cost, the proposed system can be expected to maintain the reliability and safety of operations for wind power generation.
Acknowledgements
The author thanks Dr. Matsubara Ichiro, former lecturer of Osaka University, for his help in the operation of impulse testing and for a fruitful discussion on the methodology of lightning protection. The author also thanks Mr. Yoshioka Takuma, Mr. Fujii Toshiaki and Mr. Yamashita Shogo, graduate and undergraduate students of Kansai University, for their help in the impulse tests.
5. 結(jié)論
在這篇文章中作者提出了新型的利用環(huán)形電極間隙放電器作為風(fēng)力發(fā)電機(jī)組直擊雷防護(hù)的一種方法,其中最重要和具有創(chuàng)新性的點(diǎn)在于如何控制兩個(gè)環(huán)形放電器的間距,使雷電通過(guò)間隙時(shí)不受風(fēng)速對(duì)電流弧的影響,通過(guò)1:100的風(fēng)機(jī)模型及模擬雷擊實(shí)驗(yàn)的結(jié)果清楚的表明這種方式是可行的、安全的。雖然在環(huán)形電極間隙距離大于輪轂環(huán)形電極于機(jī)艙間距時(shí)會(huì)造成輪轂環(huán)形電極與機(jī)艙的放電,但并不影響該套方案的有效性,通過(guò)后續(xù)的優(yōu)化方案這種防雷系統(tǒng)的效果也是能夠令人滿(mǎn)意的。同時(shí)作者還在運(yùn)用FDTD時(shí)差法計(jì)算,間隙通過(guò)雷電流時(shí)的電磁抵消情況,但可以肯定的是電磁能量的抵消情況應(yīng)該與實(shí)驗(yàn)結(jié)果相吻合。
當(dāng)然這套防雷系統(tǒng)仍存在一些問(wèn)題,例如這個(gè)系統(tǒng)的定位和安裝需要從工程安裝角度來(lái)解決,并且安裝后可能對(duì)機(jī)組的整體氣動(dòng)性能方面會(huì)存在怎樣的影響,還需要進(jìn)一步討論。無(wú)論如何,這種方案的提出對(duì)于機(jī)組的雷電防護(hù)、實(shí)際有效性、安全性能和可實(shí)施性都被寄予了很大希望。
特別感謝
作者感謝大阪大學(xué)前講師Matsubara Ichiro博士,在雷電脈沖測(cè)試實(shí)驗(yàn)的執(zhí)行中以及機(jī)組的防護(hù)方法上提出富有成效的建議以及幫助。同時(shí)還要感謝Yoshioka Takuma先生、Fujii Toshiaki先生和Yamashita Shogo先生這些関西大學(xué)畢業(yè)和沒(méi)有畢業(yè)學(xué)生在雷擊實(shí)驗(yàn)中給予的幫助。
【延伸閱讀】
版權(quán)與免責(zé)聲明:
凡注明稿件來(lái)源的內(nèi)容均為轉(zhuǎn)載稿或由企業(yè)用戶(hù)注冊(cè)發(fā)布,本網(wǎng)轉(zhuǎn)載出于傳遞更多信息的目的,如轉(zhuǎn)載稿涉及版權(quán)問(wèn)題,請(qǐng)作者聯(lián)系我們,同時(shí)對(duì)于用戶(hù)評(píng)論等信息,本網(wǎng)并不意味著贊同其觀點(diǎn)或證實(shí)其內(nèi)容的真實(shí)性;
本文地址:http://www.yy8811.cn/tech/show.php?itemid=7942&page=5
轉(zhuǎn)載本站原創(chuàng)文章請(qǐng)注明來(lái)源:東方風(fēng)力發(fā)電網(wǎng)
東方風(fēng)力發(fā)電網(wǎng)版權(quán)所有?2015-2024
本站QQ群:53235416 風(fēng)電大家談[1] 18110074 風(fēng)電大家談[2] 95072501 風(fēng)電交流群
東方風(fēng)力發(fā)電網(wǎng)
微信掃描關(guān)注